Henan Lanphan Industry Co.,Ltd

We adhere to the concept “loyal, responsible, being professional ” and stimulate all the staff to be of one heart and one mind, work with collective wisdom and concerted efforts, in order to provide

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Chiller Lab Equipment /

Lanphan 420W Cryogenic Cooling Lab Chiller Unit

Contact Now
Henan Lanphan Industry Co.,Ltd
Visit Website
City:zhengzhou
Province/State:henan
Country/Region:china
Contact Person:admin
Contact Now

Lanphan 420W Cryogenic Cooling Lab Chiller Unit

Ask Latest Price
Video Channel
Place of Origin :Henan, China
Brand Name :Lanphan
Certification :CE, ROHS
Supply Ability :1000 Set/Sets per Month
Packaging Details :Packing of low temperature cooling liquid circulating pump: carton or wooden case package, customized package is available.
MOQ :1 - 2 Units
Price :$772.00
Condition :NEW
Type :Water-Cooled
Voltage :220v
Dimension(L*W*H) :400*260*530mm
Weight :28kg
Warranty :1 YEAR
After-sales Service Provided :Video technical support, Online support
Power(W) :420w
Tank volume (L) :5
lowest no-load temperature(℃) :-15
Using temperature range (℃) :room temperature--15
best temperature range(℃) :5~25
Environmental relative humidity (%) :≤70
temperature display mode :liquid crystal
Sensor index :Pt100
Instrument adjusting range (℃) :±150
safety protection :delay,leakage,over current,overheat
Total machine power (W) :420W
Port :Shanghai, Tianjin, Qingdao
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Cryogenic Cooling System Laboratory Circulating Chiller

The capacity of our pump can be 5L-500L
Temperature ranges from room temperature to -120 degrees

Product Description

Lanphan 420W Cryogenic Cooling Lab Chiller Unit

The DLSB 5L-10℃ series low temperature coolant circulation pump is a low-temperature equipment that uses a compressor for mechanical refrigeration. On the basis of refrigeration, a water circulating pump is added to enable the cooled liquid to pass through the pipeline for external and internal circulation, and can provide low temperature liquid and low temperature bath. It can also be combined with a rotary evaporator, a vacuum freeze drying oven, a water circulating vacuum pump, a magnetic stirrer and the like to perform multi-functional chemical reaction operations and drug storage at a low temperature.


The DLSB 5L-10℃ series low temperature coolant circulation pump can be used in laboratories, providing the cooling environment for small capacity of sample. It is especially suitable for chemical, biological and physical laboratories that need to maintain low temperature and normal temperature conditions. It is an essential equipment for medical and health, chemical industry, food industry, metallurgical industry, colleges and universities, scientific research, genetic engineering, polymer engineering and other fields. ( The large-capacity low-temperature coolant
circulation pump can be customized according to user needs.)

Lanphan 420W Cryogenic Cooling Lab Chiller Unit

Model name DLSB 5L-10℃
Tank volume (L) 5
lowest no-load temperature(℃) -15
Using temperature range (℃) room temperature—-15
best temperature range(℃) 5~25
Environmental relative humidity (%) ≤70
Working power supply (V/HZ) single phase220-50
temperature display mode liquid crystal
temperature stability(℃) ±2
Sensor index Pt100
Instrument adjusting range (℃) ±150
set way Arbitrary adjustment of Settings in the range of use
safety protection delay,leakage,over current,overheat
output refrigerating capacity (W) 10℃ 620
0℃ 460
-10℃ 280
-20℃ -
Total machine power (W) 420
Machine current (A) 2.1
refrigerant 134A
Circulating pump Power(w) 100
Flow rate(L/min) 20
Lift(M) 4~6
external loop interface Threaded joint 12 inches
opening size(mm) 160×160
tank shape square
Internal diameter and height of liquid storage tank (mm) 170×170×170
Overall appearance size (mm) 400×260×530
Machine weight (kg) 28
fuse 5A
matching parts one set

Lanphan 420W Cryogenic Cooling Lab Chiller UnitLanphan 420W Cryogenic Cooling Lab Chiller Unit

Turn on and off:
The right turn to turn on the machine: Add the appropriate medium—connect the power with the special power supply—turn off the circulation switch—press the power button—open the circulation switch—open the switch—open the cooling equipment
The right turn to turn off the machine.Turn off the cooling equipment—turn off the switch—turn off the circulation switch(stirring switch)—turn off the outlet valve(or discharge the cooling medium)—turn off the power supply —disconnect circuit breaker—disconnect the power line from the power supply—clean the equipment.
Corollary Equipment

Lanphan 420W Cryogenic Cooling Lab Chiller Unit

Related Products

Lanphan 420W Cryogenic Cooling Lab Chiller UnitLanphan 420W Cryogenic Cooling Lab Chiller Unit

The capacity of our pump can be 5L-500L
Temperature ranges from room temperature to -120 degrees

Company Information
Lanphan 420W Cryogenic Cooling Lab Chiller Unit

Lanphan 420W Cryogenic Cooling Lab Chiller UnitLanphan 420W Cryogenic Cooling Lab Chiller Unit

Lanphan 420W Cryogenic Cooling Lab Chiller Unit

Lanphan 420W Cryogenic Cooling Lab Chiller Unit

Lanphan 420W Cryogenic Cooling Lab Chiller Unit Contact us For more details about price, packing, shipping and discount. Tel: 86-371-67447999
Web: http://www.rotovap.cn
Address: Jianshe Road, Zhongyuan District, Zhengzhou, Henan, China

Inquiry Cart 0